Thermography Surveys

How a Fenestration Professional Benefits from Use of Infrared Thermal Imaging of Doors & Windows

How a Fenestration Professional Benefits from use of Infrared Thermal Imaging of Windows and Doors

I have been in the window and door troubleshooting industry for seventeen years and I am very excited about a new tool that I added to my arsenal three years ago. Statistics show that 92% of water ingress and cold air infiltration in windows and doors is attributed to improper installation. Infrared thermography allows me to find problems and validate my diagnoses. What is really important is that the IR images can be read and understood by window and door fabricators, surveyors, installers and even homeowners. Best of all, it can lead to a solution that is the most cost-effective for that particular situation.
It is not uncommon in the industry to replace every window in a home due to a small shortcoming in the installation method or a small manufacturing defect. Misdiagnosis of a problem can cost the manufacturer, reflect badly on the factory and the installer, cost the contractor time, and importantly, add unnecessary aggravation for the homeowner. My thermal camera has become the most valued tool in my motor. When I use the camera and find a problem, or the extent of a problem, everybody wins!

 

Errors in Installation

Errors in the systematic process of installing a window or door can lead to air and water ingress as well as poor operation, and can substantially shorten the service life of the product.
No matter what the climate when winters are brutally cold and wet, and the summers are equally warm, humid and wet, a poor installation wastes money in excess heating and cooling costs. Installation of door and window products according to the manufacturers specifications for a particular location and environment, is the most desirable method and should be followed to the letter to ensure that the door or window meets or exceeds the performance level of that product.
Poor operation is usually the fault of the installer and there is no technology better than the human eye, ear, and hand to determine what the problem is and how it is to be repaired.
For issues of air infiltration, a smoke pencil, in addition to the human hand, is often the preferred method of investigation.

When it comes to water infiltration or ingress, as we like to call it, the human eye is good and has been forever – but there is absolutely no better technology to find the source and path of this intrusion than infrared thermography.

 

Use of Infrared in Finding Installation Problems

An initial, non-certified, non-calibrated water test using a garden hose is, in most cases, all that is needed to find the problem.

Other times, a blower door is employed in addition to the above water test to create a negative interior pressure similar to a storm.

For years, we have represented the window and door installers and our prime concern was water entering through the unit. When a unit leaks when it is not supposed to, the installer is held responsible in the eye of the homeowner when in fact the issue could be attributed to a fabrication defect.

This is easy to discover and the repair / remediation process is standardised by the factory. The thermogram that follows shows a glazing juncture failure where water is coming around the bottom of the insulated glass unit (IG) on a door.

In instances where we believe the water ingress is around the unit as a result of poor installation and not the fault of the product itself, we have had to resort to the destruction of the interior surface to see the exterior wall assembly and window/door frame to prove this visually, and document it using a simple moisture meter.
Infrared thermography makes the process very simple. We only have to look where we see a thermal anomaly typical of water intrusion around or under the subject unit.

The ability to document what we find with a thermogram is crucial to getting the problem resolved by the correct party.
The issue of air infiltration is one where the human hand is the best tool for discovery. Many times, a homeowner or builder will complain that a “seal failure” is causing a draft. This is impossible. In a cold climate, they are likely to sense a “thermal draft” where the warm air at the ceiling is naturally cooling, and as it drops across the face of the fenestration unit, the glass acts as a heat sink with the air losing heat rapidly, causing the sensation of a draughty window.
A true “seal failure” has very little impact on building heat loss or gain. An Insulated Glass unit (IG) was originally designed for the intent of reducing, and hopefully eliminating, interior condensation on the glass, which led to degradation of the wood fibres (wood-rot) in a wooden window.
An IG unit creates a “dead-air” space, not a vacuum, between the glass panes, which allows the indoor ambient temperature to keep the interior surface of the glass above the dew point. Prior to IG units becoming available in commercially available residential window units, a storm window was employed.
The spacer of an IGU is the only place that conductive heat loss or gain can occur. The only place on an IG unit where infrared thermography can be of use is observing and recording the heat transfer at and near the IG spacer.

The most significant areas of heat loss/gain on any fenestration unit are where the operable sash meets the unit frame employing weather-seals, and around the unit itself where it is attached to the building substrate. More heat is lost at these places of a window than at the glazing. Also, heat loss/transfer at the exposed glazing surface is unavoidable.
The use of infrared thermography in assessing the performance of a window is easy. With a Delta-T present in a static air pressure environment, the natural convection and conduction of heat transfer through and around the fenestration unit can be imaged both from the interior and the exterior. In a cold climate situation, if insulation is missing between the window / door and the building substrate, a thermal anomaly will be present.

The unit above was found to have a void in the insulation at the bottom of the aperture. The initial scan showed a cold anomaly and removal of the architrave proved this.
In more complex situations we use a blower door to simulate a constant 25 mph wind (interior air pressure – 50kPa), an interior infrared thermogram can accentuate the junctures or areas that need to be sealed and/or insulated where possible.

In reality we more often than not are able to pin point areas of issue with a simple thermography survey. We ask the householder to have all windows, doors and trickle vents closed and to have the central heating on (in every room to be assessed) for at least and hour before our inspector is due to arrive. The higher the temperature differential between inside and outside the clearer the thermal image taken. Our inspector will accurately detail inner room temperatures, outside temperatures and the RH (relative humidity) in each location assessed. Moisture laden air in a particular room plays a large part in Fenestration issues pertaining to condensation and by recording RH and using thermal imaging our inspectors can track thermal anomalies allowing remediation (to be recommended – if required) or guiding the householder to other issues that may require attention.

More Services

Damp Testing and Acousting Surveys

Acoustic Testings

Learn about acoustic testing and surveys carried out in the fenestration industry

Sound insulation testing or an Acoustic survey as we prefer to call it in the Fenestration industry is a test carried out to ensure your installation demonstrates acceptable levels of airborne sound insulation performance outlined 

Damp Testing

Learn about damp testing reports based upon the damp, condensation, mould pertaining to fenestration.

This type of report looks into the relative humidity of the property and the way in which ventilation is provided into the establishment. Moisture laden air causes havoc with high quality energy-efficient window installations....